DEYE 16KW 3 PHASE HYBRID INVERTER

3,740,000.00

Category: Brand:
Modell SUN-14K-SG05LP3
-EU-SM2
SUN-15K-SG05LP3
-EU-SM2
SUN-16K-SG05LP3
-EU-SM2
SUN-18K-SG05LP3
-EU-SM2
SUN-20K-SG05LP3
-EU-SM2
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range (V) 40-60
Max. Charging/Discharging Current (A) 260 280 300 330 350
Charging Strategy forLi-ion Battery Self-adaption to BMS
Number of Battery Input 2
PV String Input Data
Max. PV Access Power (W)
28000 30000 32000 36000 40000
Max. PV Input Power (W) 22400 24000 25600 28800 32000
Max. PV Input Voltage (V) 800
Start-up Voltage (V) 160
MPPT Voltage Range (V) 160-650
Rated PV Input Voltage (V) 550
Max. Operating PV Input Current (A) 36+36
Max. Input Short-Circuit Current (A) 54+54
No.of MPPT Trackers/
No.of Strings MPP Tracker
2/2+2
AC Input/Output Data
Rated AC Input/Output Active Power (W) 14000 15000 16000 18000 20000
Max. AC Input/Output Apparent Power (VA) 15400 16500 17600 19800 22000
Rated AC Input/Output Current (A) 21.3/20.3 22.8/21.8 24.3/23.2 27.3/26.1 30.4/29
Max. AC Input/Output Current (A) 23.4/22.4 25/24 26.7/25.6 30/28.7 33.4/31.9
Max. Continuous AC Passthrough (grid to load) (A) 70
Peak Power (off-grid) (W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage 220/380V, 230/400V  0.85Un-1.1Un  3L+N+PE
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Component of Grid <0.5% In
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 97.0%
MPPTEfficiency >99%
Equipment Protection
Integrated
DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection,
AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring,
Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional),
Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch,
DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level
Surge Protection Level TYPE II(DC),TYPE II(AC)
Interface
LCD/LED Display LCD
Communication Interface
WIFI, RS485, CAN
General Data
Operating Temperature Range (℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 3000m
Noise(dB) <60
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated (solar), Isolated (battery)
Over Voltage Category OVC II(DC), OVC III(AC)
Cabinet Size (WxHxD mm) 456×750×268.5 (Excluding Connectors and Brackets)
Weight (kg) 51.9
Type of Cooling Intelligent Air Cooling
Warranty 5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
Grid Regulation IEC 61727, IEC 62116,CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99,VDE-AR-N 4105
Safety / EMC Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2