DEYE 8KW 3 PHASE HYBRID INVERTER

2,695,000.00

  • 100% unbalanced output, max. output up to 50% rated power for each phase
  • AC couple to retrofit existing solar system
  • Max. 10 pcs parallel for on-grid and off-grid
    operation; support multiple batteries parallel
  • Max. charging/discharging current of 240A
  • Support storing energy from diesel generator
  • 48V low voltage battery, transformer isolation design
  • 6 time periods for battery charging/discharging
Category:
Model SUN-5K-SG04LP3-EU SUN-6K-SG04LP3-EU SUN-8K-SG04LP3-EU SUN-10K-SG04LP3-EU SUN-12K-SG04LP3-EU
Battery Input Data
Battery Type Lead-acid or Lithium-ion
Battery Voltage Range(V) 40-60
Max.Charging/Discharging Current(A) 120 150 190 210 240
Charging Strategy for Li-ion Battery Self-adaption to BMS
Number of battery input 1
PV String Input Data
Max. PV Access Power (W)
10000 12000 16000 20000 24000
Max. PV Input Power(W) 7500 9000 12000 15000 18000
Max. PV Input Voltage(V) 800
Start-up Voltage(V) 160
MPPT Voltage Range(V) 200-650
Rated PV Input Voltage(V) 550
Max. Operating PV Input Current (A) 13+13 26+13
Max. Input Short-Circuit Current (A) 17+17 34+17
No.of MPP Trackers/No.of Strings MPP Tracker 2/1+1 2/2+1
AC Input/Output Data
Rated AC Input/Output Active Power(W) 5000 6000 8000 10000 12000
Max. AC Input/Output Apparent Power (VA) 5500 6600 8800 11000 13200
Rated AC Input/Output Current(A) 7.6/7.2 9.1/8.7 12.1/11.6 15.2/14.5 18.2/17.4
Max. AC Input/Output Current(A) 8.4/8 10/9.6 13.4/12.8 16.7/15.9 20/19.1
Max. Continuous AC Passthrough (grid to load)(A) 40
Peak Power (off-grid)(W) 2 times of rated power, 10s
Power Factor Adjustment Range 0.8 leading to 0.8 lagging
Rated Input/Output Voltage 220/380V,230/400V  0.85Un-1.1Un  3L+N+PE
Rated Input/Output Grid Frequency/Range(Hz) 50/45-55, 60/55-65
Total Current Harmonic Distortion THDi <3% (of nominal power)
DC Injection Current <0.5%ln
Efficiency
Max. Efficiency 97.6%
Euro Efficiency 97.0%
MPPT Efficiency >99%
Equipment Protection
Integrated
DC Reverse Polarity Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage
Protection, AC Output Short Circuit Protection, DC Component Monitoring, Arc Fault Circuit Interrupter
(optional), Anti-islanding Protection, DC Switch, Insulation Impedance Detection,
Residual Current Detection
Surge Protection Level TYPE II(DC), TYPE II(AC)
Interface
LCD/LED Display LCD
Communication Interface
WIFI, RS485, CAN
General Data
Operating Temperature Range(℃) -40 to +60℃, >45℃ Derating
Permissible Ambient Humidity 0-100%
Permissible Altitude 2000m
Noise(dB) <55
Ingress Protection(IP) Rating IP 65
Inverter Topology Non-Isolated (solar), Isolated (battery)
Over Voltage Category OVC II(DC),OVC III(AC)
Cabinet size(W*H*D)[mm] 422×658×254(Excluding connectors and brackets)
Weight[kg] 38
Warranty 5 Years/10 Years
the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy
Type Of Cooling Intelligent air cooling
Grid Regulation IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002,
OVE-Richtlinie R25, G99, VDE-AR-N 4105
Safety EMC/Standard IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2

There are no reviews yet.

Be the first to review “DEYE 8KW 3 PHASE HYBRID INVERTER”

Your email address will not be published. Required fields are marked *